Operational specification
Measuring Range:
-250°C – 1350°C
Resolution:
TA (Temperature Ambient)
(TA – 55°C) < T < (TA + 225°C): 0.1°C else: 0.7°C
Accuracy**:
0.4%FS ± 1°C @ TA = 25°C
1.5%FS±1°C@TA =25°C,T<-80°C
Measuring Frequency***:
Every 10 sec
Report frequency*:
Reports every 2 min. Or immediately if trigger for critical data transmission is reached, see below
Trigger for Critical Data Transmission***:
10oC change in measurement
Electronics Operating Environment:
Ambient Temperature: -40 – 85 oC
Relative Humidity: 0-80%
Altitude < 2000m above sea level
Pollution degree: 3
IP Grade ****:
IP 67, wet conditions, indoor use.
Cleaning:
Wipe clean with a damp cloth
Radio Frequency:
863-870 MHz / 902-928 MHz
Battery Type:
Lithium Manganese Dioxide, 3.0V
Expected Operating Time *****:
Up to 10 Years
* Depends on choice of Type K probe.
** The accuracy specification does not include the error of your probe.
Please see your probe manufacturers datasheet for details.
*** Adjustable on request.
**** IP grade does not include sensing probe and its connector.
***** Depends on measurement frequency, amount of critical data transmissions
and ambient temperature.
Physical specification
Materials:
Polyurethane / Ni-Cu-Ni Coated Neodymium Magnet
Connection Type:
IEC Miniature Connector Type K
Dimensions LxWxH:
53x71x14 mm
Regulatory
Certifications:
CE marking
UK CA
FCC
Industry Canada
Directives/Standard:
RED 2014/53/EU Radio Equipment Regulations 2017