Operational specification
PT100 Measuring range:
-50°C to +250°C
Resolution:
0.1°C
Accuracy:
0.5°C + 0.005 x t
Measuring Frequency*:
Every 3 sec
Report Frequency*:
Reports every 2 min. Or immediately if trigger for critical data transmission is reached, see below
Trigger for Critical Data Transmission*:
2°C change in measurement
Electronics Operating Environment:
Ambient temperature: -40 – 85 °C
Relative humidity: 0-100%
Altitude: < 2000m above sea level
Pollution degree: 4
IP Grade:
IP 67, wet conditions, indoor use
Radio Frequency:
863-870 MHz / 902-928 MHz
Battery Type:
Li-SOCl2, 3.6V
Expected Operating Time**:
Up to 10 years
* Adjustable on request
** Depends on measurement frequency, amount of critical data transmissions and ambient temperature
Physical specification
Materials:
Sensor: POLYblend 65 FS / TPU
PT100-element: 316 Stainless Steel
Connection Type:
100 cm PFA insulated twisted wires
Process Connection:
1⁄4” BSPP
Dimensions LxWxH:
Sensor: 37x23x14mm
PT100 element: 6x100mm
Regulatory
Certifications:
CE marking
UK CA
FCC
Industry Canada
Directives/Standard:
IEC 61010-1:2010
FCC Part 15C
RED 2014/53/EU Radio
Equipment Regulations 2017